AMTEC Testing Room
QA/QC Quality Inspection & Testing Equipment System
Fully equipped with 3D X-Ray scanning system, Electronic microscope, LCR measurement and moisture-proof storage cabinet to protect components
To ensure the error rate is at a minimum level below 50 PPM, AMTEC synchronously invests in the most modern error analysis and measurement equipment system in the EMS industry.
The multi-directional X-Ray scanner system allows detailed inspection of the solder joint structure underneath BGA, QFN and LGA chip components that cannot be observed with the naked eye or microscope.
Electron microscope with high magnification for Cross-section analysis, LCR meter automatically classifies passive components before loading into feeder, and electronic moisture-proof cabinet system preserves moisture-sensitive components (MSD) according to J-STD-033 standard.